CK — Solenoid Diaphragm Metering Pump

Metering Pump · Electromagnetic

CK · Solenoid Diaphragm Metering Pump

Solenoid diaphragm pump. CKS manual stroke or CKZ automatic with 4–20 mA, pulse batching and level interlock. PVC or PVDF wet end, 110/220 V.

  • Flow range: 3–17 L/h
  • Max pressure: 10 bar
  • Accuracy: ±2%

No price on site — inquiry only.

Get Quote

Specifications

ParameterValue
Max flow17 L/h
Max back pressure10 bar
Accuracy±2%
MaterialsPVC / PVDF
Controlstroke / 4–20 mA
Explosion-proof—
Weight4 kg
PortsPE 4/6
Power20–40 W · 110/220 V

Max flow and max back pressure are the opposite ends of this series. Each model row pairs the flow with the back pressure of that size.

Accuracy is the figure printed for this series. Fluid, back pressure and turndown are confirmed on the quote.

Suction, viscosity and temperature

Suction lift, inlet pressure, viscosity, liquid temperature and ambient temperature belong on the inquiry, together with the medium and concentration.

Model specifications

ModelFlow (L/h)Pressure (bar)Pump speed (SPM)Power (W)
CKS17 / CKZ1717130040
CKS12 / CKZ1212530040
CKS07 / CKZ0781030040
CKS09 / CKZ099216020
CKS05 / CKZ055516020
CKS04 / CKZ044816020
CKS03 / CKZ0331016020

Materials

Materials science →
  • PVC

    Pump head, valves, day tanks

    About 0–50 °C. Softens above that.

  • PVDF

    Preferred plastic head for oxidizers

    About −20–120 °C. Caustic service much lower.

Temperature windows below describe the listed materials. Liquid temperature for the pump still depends on the head, the chemical and the pressure, and is confirmed on the quote.

Pump type

Low-flow solenoid dosing for chlorine, acids and pools.

Electromagnetic →

Documents

Main drawings ship with the quote. CAD is not published on the site.

Open datasheet pageDownloads

FAQ

Why are there no prices?

This is an inquiry catalog. Duty, materials and certificates change the offer. Engineering replies within one business day.

What flow and pressure does this model cover?

Series ends: up to 17 L/h and up to 10 bar. Those ends are separate. Where a model table is shown, each row pairs flow with that size's back pressure. The duty is confirmed on the quote.

Which wet-end materials are listed?

PVC / PVDF. Confirm medium, concentration and temperature on the quote.

Which certificates do you hold?

Certificates are confirmed on the quote. They are not listed on this site. EAC is arranged per order.

How do I inquire this model?

Open Get a Quote, keep the model number, and send duty and country. Engineering replies within one business day.